COMTRAN Reconstruction

J28-6169 · January 1962

06.02.04

PDF page 115 of 221. Download the scanned PDF

The page as scanned

The scan of PDF page 115 of J28-6169
Select the scan to open it at full size.

The text read off it

[06.02.04]

B. Object-Time Tape Assignment

The assignment of physical units to the various files in the object program is performed by the Loader by processing the symbolic 'unit' columns (18-21 and 22-25) in the FILE cards which precede the binary object deck. For referencing purposes, the following definition of permissible symbolic units which may appear on the FILE cards is repeated. In the definition of permissible symbolic units requested by the programmer, the notation is as follows:

Symbol Meaning
X is a true channel request and may be A, B, C, D, E, F, G, H.
Y is a symbolic channel request and may be S, T, U, V, W, X, Y, Z.
k is a relative unit request and may be 1, 2, 3, 4, 5, 6, 7, 8, 9, 0.
M is a true tape model request and may be II or IV

The permitted unit requests are:

a. blank
b. Model only M
c. True channel X
d. Symbolic channel Y
e. True channel, Model XM
f. True channel, Relative unit X(k)
g. Symbolic channel, Model YM
h. Symbolic channel, Relative unit YK or Y(k)
i. Symbolic channel, Relative unit, Model YKM
j. For secondary unit assignment after all other requests have been fulfilled *

In addition, the programmer may request the following SYStem units and card equipment.

Symbolic Unit(s) Meaning
IN, IN1, IN2 System input units
OU, OU1, OU2 System output units
PP, PP1, PP2 System punch units
UT1, UT2, UT3, UT4 System Utility tapes
RDX Card reader, channel X
PRX Printer, channel X
PUX Punch, channel X