[90.02.28]

SYS)254

TRA     SYS)254
SOURCE-CONTROL-WORD-TYPE-ID
TARGET CONTROL-WORD TYPE-SD

This MOVPAK subroutine converts from internal decimal in the AC or AC-MQ to scientific decimal. CONTROL-WORD-TYPE-ID has the same format as described under SYS)250 and CONTROL-WORD-TYPE-SD has the same format as described under SYS)248.

SYS)255

TRA     SYS)255
TARGET-CONTROL-WORD-TYPE-SD

This MOVPAK subroutine converts from double precision floating point in the AC-MQ to scientific decimal. The CONTROL-WORD-TYPE-SD has the same form as described under SYS)248.

SYS)256

TRA     SYS)256
SOURCE-CONTROL-WORD-TYPE-SD

This MOVPAK subroutine converts from scientific decimal to double precision floating point leaving the results in the AC-MQ. CONTROL-WORD-TYPE-SD has the same form as described under SYS)248.

SYS)257

TSX     SYS)257, 4
TARGET-CONTROL-WORD-TYPE-ID

This MOVPAK subroutine converts from double precision floating point in the AC-MQ to internal decimal leaving the results in the AC or AC-MQ. TARGET-CONTROL-WORD-TYPE-ID has the same form as described under SYS)250.

SYS)258

TSX     SYS)258, 4
SOURCE-CONTROL-WORD-TYPE-ID

This MOVPAK subroutine converts from internal decimal in the AC or AC-MQ to double precision floating point leaving the results in the AC-MQ. SOURCE-CONTROL-WORD-TYPE-ID has the same form as described under SYS)250.

SYS)260

This SYS number may appear in a GET calling sequence to the IOCS Read routine:

TSX     IOC)8, 4
PZE     FILENAME, , SYS)260
PZE     SYS)265, , SYS)283
IOCDN*  BL)NN, , 14

The SYS)260 subroutine prints an error message indicating processing terminated due to record length error.